Don't have an account?
| Attribute name | Attribute value |
|---|---|
| Main | |
| Output voltage | 240 V, 220 V |
| Provided equipment | user manual, 1 RS-232 configuration cable, 1 USB cable, 1 IEC 60320 C19 to Australian power cable |
| Rated power in W | 2400 W |
| Main Input Voltage | 230 V |
| Rated power in VA | 3000 VA |
| Product or component type | uninterruptible power supply (UPS) |
| Cable length | 4.86 ft |
| Number of cables | 1 |
| Input voltage | 240 V, 220 V |
| Curve proportional loss | 0.0341 |
| UPS type | double conversion online |
| Output voltage | 230 V |
| Number of tare power | 32 W |
| Curve load minimum | 2 % |
| Number of battery free slots | 0 |
| Curve square loss | 0.0319 |
| Curve X-axis title | load |
| Curve X-axis minimum | 0 % |
| Curve Y-axis maximum | 100 % |
| Curve Y-axis units | percentage |
| Output connection type | 4 Australian |
| Liquid value | 0 |
| Wave type | sine wave |
| Mounting preference | no preference |
| Battery charger power | 118 W rated |
| Output frequency | 50/60 Hz +/- 3 Hz sync to mains |
| Number of battery filled slots | 0 |
| Surge energy rate | 600 J |
| Curve Y-axis minimum | 50 % |
| Battery power in VAH | 473 VAh runtime |
| Curve fixed loss | 0.0176 |
| Curve X-axis maximum | 100 % |
| Curve X-axis units | percentage |
| Curve load maximum | 100 % |
| Curve test cond ID | Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output. |
| Battery recharge time | 4 h |
| UPS size | WS |
| Number of power module filled slots | 0 |
| Input Connection Type | IEC 60320 C20 |
| Redundant | No |
| Battery curve | D |
| Curve Y-axis title | efficiency |
| Show note OP temperature | No |
| Maximum configurable power in VA | 3000 VA |
| Maximum configurable power in W | 2400 W |
| Curve equation | efficiency |
| Number of power module free slots | 0 |
| Environmental | |
| Operating altitude | 0...3000 m |
| Acoustic level | 50 dBA |
| Relative humidity | 0-95 % non-condensing |
| Ambient air temperature for storage | -20-50 °C |
| IP degree of protection | IP20 |
| Storage altitude | 0-15000 m |
| Ambient air temperature for operation | 0-40 °C |
| Storage Relative Humidity | 0-95 % non-condensing |
| Physical | |
| Depth | 42.5 cm |
| Width | 19 cm |
| Colour | black (RAL 7010) |
| Mounting position | vertical |
| Mounting mode | not rack-mountable |
| Mounting location | front |
| Net weight | 26.8 kg |
| USB compatible | No |
| Height | 33.6 cm |
| Input | |
| Input voltage limits | 160...280 V full load, 110...285 V half load |
| Network frequency | 40...70 Hz auto sensing |
| Output | |
| Efficiency | 88 % (full load) |
| Crest factor | 3 : 1 |
| Graph display | 1 |
| Bypass type | internal bypass (automatic and manual) |
| Conformance | |
| Standards | EN/IEC 62040-2:2018, EN/IEC 62040-2:2006/AC:2006, EN/IEC 62040-1:2019/A11:2021 |
| Product certifications | CE |
| Batteries & Runtime | |
| Battery design life | 2 year(s) |
| Battery type | lead-acid battery |
| Battery voltage | 72 V |
| UPS design life | 3 year(s) |
| Battery life | 3-5 year(s) |
| Communications & Management | |
| Control panel | multifunction LCD status and control console |
| Free slots | 1 |