Don't have an account?
| Attribute name | Attribute value |
|---|---|
| Main | |
| Electrical circuit type | OSSD pair, antivalent pair, PNP pair, NC pair |
| Safety reliability data | type = B conforming to IEC 61508-1, SFF > 99% conforming to IEC 61508-1, PFHd = 1.61E-09 conforming to IEC 61508-1, HFT = 1 conforming to IEC 61508-1, SFF > 99% conforming to IEC 62061, PFHd = 1.61E-09 conforming to IEC 62061, HFT = 1 conforming to IEC 62061, PFHd = 1.61E-09 conforming to ISO 13849-1, Dcavg >= 99 % conforming to ISO 13849-1, MTTFd > 30 years conforming to ISO 13849-1 |
| Safety module application | monitoring of pressure-sensitive 4-wire protective devices, for emergency stop, guard and light curtain monitoring, monitoring antivalent contacts |
| Safety module name | XPSUAK |
| Range of product | Harmony Safety Automation |
| [Us] rated supply voltage | 48...240 V AC/DC - 10...10 % |
| Safety level | can reach SIL 1 for normally closed relay contact conforming to IEC 61508, can reach SILCL 1 for normally closed relay contact conforming to IEC 62061, can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1, can reach SIL 3 for normally open relay contact conforming to IEC 61508, can reach SILCL 3 for normally open relay contact conforming to IEC 62061, can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1 |
| Function of module | monitoring 1 PNP + 1 NPN sensor, proximity sensor monitoring, sensing mat/edges, monitoring of electro-sensitive protection equipment (ESPE), RFID switch, light curtain monitoring, magnetic switch monitoring, monitoring 2 PNP sensors, guard monitoring with 1 or 2 limit switches, emergency stop button with 2 NC contacts |
| Connections - terminals | removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel, removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel, removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor, removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor, removable spring terminal block, 0.2...2.5 mm² solid or flexible |
| Product or component type | safety module |
| Complementary | |
| Synchronisation time between inputs | 4 s, 2 s, 0.5 s |
| Input protection type | internal, electronic |
| Maximum line resistance | 500 Ohm |
| Power consumption in W | 3.0 W 48 V DC |
| Auxiliary contact composition | 2 NO + 1 NC |
| [Ie] rated operational current | 1 A DC-13 for normally closed relay contact, 3 A DC-1 for normally closed relay contact, 1 A AC-15 for normally closed relay contact, 3 A AC-1 for normally closed relay contact, 3 A DC-13 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A AC-1 for normally open relay contact |
| Power consumption in VA | 6.5 VA 240 V AC 50/60 Hz |
| Input compatibility | 3-wire proximity sensors PNP, OSSD pair conforming to IEC 61496-1-2, antivalent pair conforming to ISO 14119, normally closed circuit conforming to ISO 13850, mechanical contact conforming to ISO 14119, XC limit switch conforming to ISO 14119, normally closed circuit conforming to ISO 14119 |
| Number of inputs | 2 safety input 24 V DC 5 |
| Associated fuse rating | 10 A gG for NO relay output circuit conforming to IEC 60947-1 |
| Input/output type | semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related |
| Minimum output voltage | 12 V for relay output |
| Height | 100 mm |
| Number of outputs | 3 on/off configurable pulsed output |
| Depth | 120 mm |
| Width | 22.5 mm |
| [Ui] rated insulation voltage | 250 V (pollution degree 2) conforming to IEC 60947-1 |
| Type of start | automatic/manual/monitored |
| Net weight | 0.200 kg |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
| [Ith] conventional free air thermal current | 8 A |
| Minimum output current | 10 mA for relay output |
| Mounting support | 35 mm symmetrical DIN rail |
| Environment | |
| Relative humidity | 5-95 % non-condensing |
| IP degree of protection | IP54 (mounting area) conforming to IEC 60529, IP40 (housing) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 |
| Ambient air temperature for operation | -25-55 °C |
| Standards | IEC 62061 functional safety standard, ISO 13849-1 functional safety standard, IEC 61508-7 functional safety standard, IEC 61508-6 functional safety standard, IEC 61508-5 functional safety standard, IEC 61508-4 functional safety standard, IEC 61508-3 functional safety standard, IEC 61508-2 functional safety standard, IEC 61508-1 functional safety standard, IEC 60947-5-1 |
| Product certifications | cULus, TÜV |