| Attribute name | Attribute value |
|---|---|
| Main | |
| [Ie] rated operational current | 800 A (at <60 °C) at <= 440 V AC-3, 1050 A (at <40 °C) at <= 1000 V AC-1 |
| Utilisation category | DC-5, DC-3, DC-1, AC-8a, AC-8b, AC-6b, AC-6a, AC-5b, AC-5a, AC-4, AC-3e, AC-3, AC-1 |
| [Uc] control circuit voltage | 48...130 V DC, 48...130 V AC 50/60 Hz |
| Device short name | LC1G |
| Range | TeSys |
| Control circuit voltage limits | drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C), operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C) |
| Range of product | TeSys Giga |
| Poles description | 3P |
| Product or component type | contactor |
| Contactor application | motor control, power switching |
| [Ue] rated operational voltage | <= 460 V DC, <= 1000 V AC 50/60 Hz |
| Complementary | |
| Compatibility code | LC1G |
| Electrical durability | 150 cycles AC-4 at Ue 400 V, 500 cycles AC-3e at Ue 400 V, 500 cycles AC-3 at Ue 400 V, 300 cycles AC-1 at Ue 400 V |
| Number of modules per PLC per PC | 1 |
| Associated fuse rating | 1250 A gG at <= 690 V, 630 A aM at <= 690 V for motor, 800 A aM at <= 440 V for motor |
| Height | 388.5 mm |
| Inrush power in W | 440 W |
| [Ui] rated insulation voltage | 1000 V |
| Overvoltage category | III |
| Mechanical durability | 5 Mcycles |
| Coil technology | built-in bidirectional peak limiting |
| Inrush power in VA | 560-560 VA |
| Net weight | 17.3 kg |
| Auxiliary contact composition | 1 NO + 1 NC |
| Average impedance | 0.000065 Ohm |
| Power dissipation per pole | 42 W AC-3 - Ith 800 A, 70 W AC-1 - Ith 1050 A |
| Product certifications | EU-RO-MR by DNV-GL, UKCA, CE, EAC, cULus, CCC, CB Scheme |
| [Icw] rated short-time withstand current | 1.7 kA - 10 min, 2.6 kA - 3 min, 3.6 kA - 1 min, 4.6 kA - 30 s, 5.5 kA - 10 s |
| Tightening torque | 58 N.m |
| Operating time | 15...50 ms opening, 40...70 ms closing |
| Irms rated making capacity | 7640 A at 440 V |
| Rated breaking capacity | 5870 A at 440 V |
| [Ith] conventional free air thermal current | 1050 A (at 40 °C) |
| Connection pitch | 70 mm |
| Motor power hp | 800 hp at 575/600 V 60 Hz, 700 hp at 460/480 V 60 Hz, 350 hp at 230/240 V 60 Hz, 300 hp at 200/208 V 60 Hz |
| Motor power kW | 400 kW at 1000 V AC 50/60 Hz (AC-4), 475 kW at 690 V AC 50/60 Hz (AC-4), 400 kW at 500 V AC 50/60 Hz (AC-4), 375 kW at 440 V AC 50/60 Hz (AC-4), 355 kW at 415 V AC 50/60 Hz (AC-4), 375 kW at 400 V AC 50/60 Hz (AC-4), 200 kW at 230 V AC 50/60 Hz (AC-4), 450 kW at 1000 V AC 50/60 Hz (AC-3), 560 kW at 690 V AC 50/60 Hz (AC-3), 500 kW at 500 V AC 50/60 Hz (AC-3), 450 kW at 440 V AC 50/60 Hz (AC-3), 450 kW at 415 V AC 50/60 Hz (AC-3), 450 kW at 400 V AC 50/60 Hz (AC-3), 250 kW at 230 V AC 50/60 Hz (AC-3), 450 kW at 1000 V AC 50/60 Hz (AC-3e), 560 kW at 690 V AC 50/60 Hz (AC-3e), 425 kW at 500 V AC 50/60 Hz (AC-3e), 375 kW at 440 V AC 50/60 Hz (AC-3e), 355 kW at 415 V AC 50/60 Hz (AC-3e), 335 kW at 400 V AC 50/60 Hz (AC-3e), 200 kW at 230 V AC 50/60 Hz (AC-3e) |
| Depth | 266 mm |
| Width | 211 mm |
| Hold-in power consumption in VA | 12-12 VA |
| Maximum operating rate | 150 cyc/h AC-4, 300 cyc/h AC-1, 600 cyc/h AC-3e, 600 cyc/h AC-3 |
| Connections - terminals | control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end, control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end, control circuit: push-in 2 0.5-1.0 mm² with cable end, control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end, control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end, power circuit: bolted connection, power circuit: lugs-ring terminals 1 185-185 mm², power circuit: bar 2 - busbar cross section: 52 x 20 mm |
| Pole contact composition | 3 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Hold-in power consumption in W | 8.8-8.8 W |
| Mounting support | plate |
| Standards | JIS C8201-5-1, JIS C8201-4-1, CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-5-1, EN/IEC 60947-4-1 |
| Environment | |
| Mechanical robustness | shocks 15 gn 11 ms contactor closed, shocks 10 gn 11 ms contactor open, vibrations 5-300 Hz 4 gn contactor closed, vibrations 5-300 Hz 2 gn contactor open |
| Ambient air temperature for storage | -60-80 °C |
| Permissible ambient air temperature around the device | -40-70 °C at Uc |
| Colour | dark grey |
| IP degree of protection | IP2X front face with shrouds conforming to VDE 0106, IP2X front face with shrouds conforming to IEC 60529 |
| Protective treatment | TH |
| Ambient air temperature for operation | -25-60 °C |