This is an integrated solution for monitoring multi-circuits and power quality by using a single meter. The meter is designed for retrofit and is used for critical power operations in data centres, facilities and energy management in buildings. Allow monitoring of loads up to 4000A with utility grade accuracy on all branch channels. This combination include 1 retrofit element for current transformers in order to measure values for 42 branch circuits. Allow measurement of energy, power demand, instantaneous power, current, harmonic, voltage and more - in total or per phases. Devices can be connected in dasy-chain thanks to CAT5 or CAT6 straight-through Ethernet cable. The HDPM6000 series can also maintain multiple, concurrent sessions with EPMS, DCIM or BMS applications via the Modbus, SNMP and BACnet IP protocols. This variant provides waveform capture functionality without the need for additional proprietary software. The unit need to be supplied in 24VDC, an adaptator is available to convert 480VAC (264V to 575VAC) network to needed voltage. Input reference voltage can be configured between 120 to 480VAC, frequency is calibrated for 50Hz. The head unit dimensions are 222mm in width, 51mm in height and 122mm in depth connector included. The retrofit module dimensions are 173mm in width connector included, 64mm in height and 173.48mm in depth. Certified for IEC61326-1 and EN61326-1:2020, related to Industrial Electromagnetic Environment. The elements can be mounted on a DIN rail thanks to the clips at the back side. As mentionned previously, this bundle include the PowerLogic HDPM6000 head unit plus a retrofit module 42-circuits. For the waveform capture a SD card is needed, several download options will be available. Could be associated with a touchscreen display, that could provide information from up to 4 head units. Integration of EcoStruxure Power Monitoring Expert and Power Operation features for possible software monitoring. The system PowerLogic HDPM6000 can help you identify increased harmonics in the rack servers to detect a potential disruption. Thanks to daisy-chain, it is possible to connect additional modules if the head unit capacity isn't exceeded.

Products specifications

Attribute name Attribute value
Main
Device short name HDPM6000
Device application retrofit installation
[Us] rated supply voltage 24 V DC
Energy management cost management, measurement, asset management
Range PowerLogic
Product name PowerLogic HDPM6000
Market segment critical buildings, non-critical buildings, healthcare, industrial buildings, data center
Product or component type multi-circuit energy meter
Type of measurement power factor average, power factor per channel, frequency, reactive power all channels, reactive power per channel, apparent power all channels, apparent power per channel, active power all channels, active power per channel, active energy all channels, active energy per channel, current all channels, current per channel
Variant equipped
Power quality analysis total harmonic distortion,  waveform capture
Network frequency 50 Hz
Complementary
Noise level 0-65 dB
Measurement category category III
Provided equipment 1 retrofit module 42-circuit
Web services real time viewing of data, viewing of captured waveform, controller configuration, web page
Analogue input type Rogowski coil, external CT
Poles description 3P + N + E, 3P + E, 2P + E
Measurement accuracy +/- 1 %
Number of inputs 1 temperature sensor, 42 current transformer 20...4000 A
Communication of data percentage of load, reading of measurements, power quality
Communication port protocol BACnet, SNMP, Modbus, TCP/IP
Memory capacity 8 GB
Sampling rate 128 samples/cycle
Measurement voltage 480-480 V AC 50 Hz, 415-415 V AC 50 Hz, 400-400 V AC 50 Hz, 380-380 V AC 50 Hz, 208-208 V AC 50 Hz, 120-120 V AC 50 Hz
Communication port support I/O bus RJ45, RS485 screw block terminal, 2 RJ45: ETHERNET
Environment
Operating altitude <= 2000 m
Relative humidity 5-90 %
Ambient air temperature for storage -40-85 °C
Mounting mode by screws, clipped
Type of installation indoor
Pollution degree 2
Mounting support enclosure, 35 mm DIN rail
Ambient air temperature for operation -20-60 °C
Only registered users can write reviews

PowerLogic HDPM6000 bundle with 42-circuits retrofit module, calibrated for 50 Hz, 480 V with waveform capture

Old price: $16,621.00 inc GST
$12,008.67 inc GST
Picture of Support 24/7

Support 24/7

Supporting electricians, OEMs, and switchboard builders with fast, accurate support.
Picture of Easy Returns

Easy Returns

One return policy for all products, we replace faulty ordered products.
Picture of Fast Shipping

Fast Shipping

Generally our delivery times are within 1-3 days from your order!
Picture of Free Delivery

Free Delivery

Order over $499 and free shipping is unlocked on us.